Installation Video Guide

Instructions

  1. Contact support once you are on site (1-855-885-4888)
  2. Find package (Ask GC/GM where package is located)
  3. Test sensor comms (Hook sensor directly into switch, confirm if POE port, or POE Injector)
  4. Send photos (Network room, network switch, 2x Wide angle at each entrance from inside the store)
  5. Send measurements (Mounting Height, Entrance Width, Distance to mockup location from entrance) (mockup provided by tech support)
  6. Check above ceiling at mockup location for clearance for recessed kit (1 foot wide, and 1 foot high above ceiling)
  7. Once approved to proceed with install by Support, make 147mm hole for recessed kit, and mount sensor in mockup position.
  8. Send photos of cable path for new cable run
  9. Run cable, and terminate cable run with T568B
  10. Mount sensor in mockup position (mockup provided by tech support)
  11. Send photo’s (Wide angle shot of entrance, close up of sensor, labeled network cables, where POE Injector is left)
  12. Send network switch info (Switch make and model, port number for each sensor, patch panel port number for each sensor)
  13. Count test (Stand under sensor to verify sensor height, perform walk tests as directed by Prodco Support 15 in/15 out)

Full Guide